GE / Alstom D30 Line Distance Protection System

SKU: GE_D30 Categories: ,

Description

GE / Alstom D30 Line Distance Protection System

GE MiCOM D30 Relay is a cost-effective distance protection system suitable for primary protection of sub-transmission lines and as a backup protection for HV, EHV lines, reactors and generators. The D30 provides five zones of phase and ground distance protection along with complete overcurrent and voltage protection functions intended for three-pole tripping applications. The D30 comes with versatile automation features using custom pilot schemes, which can be built.

GE MiCOM D30 Relay Key Benefits

• Cost effective, five zone quad or mho, phase and ground distance protection
• Advanced IEC 61850 Ed. 1 and Ed. 2 certified implementation, complete settings via SCL files and flexible process bus support (IEC 61850-9-2LE or IEC 61850-9-2 Hardfiber) ensures interoperability, device managing optimization and reduced cost of ownership
• Routable GOOSE (R-GOOSE) enables GOOSE messages going beyond the substation, which enables wide area protection and control applications
• Programmable logic for building customized pilot schemes
• Reduced relay-to-relay wiring and associated installation costs
• Simplified teleprotection interfaces with direct I/O communications hardware
• Robust network security enabling Critical Infrastructure Protection
• Application flexibility
• Ambient temperature monitoring
• Application flexibility with multiple I/O options including high density I/O, programmable logic, modularity, and specific customization
• An integrated large, full color display, provides real-time visualization and control of the protected bay, via a bay mimic as well as annunciator functionality and graphical visualization of phasors

Applications
• Overhead sub-transmission lines and underground cables including series-compensated lines
• Circuits requiring three-pole autoreclosing and independent synchrocheck supervision
• Circuits with in-zone power transformers
• Secure application with Capacitively-Coupled Voltage Transformers (CCVTs)
• Backup protection for generators, transformers and reactors

We offer GE’s century long tradition of power system innovation. From generators to transmission lines, to motors and beyond, we ensure dependable, safe power worldwide. GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems. Explore GE numerical Relays portfolio with us!

Reviews

There are no reviews yet.

Be the first to review “GE / Alstom D30 Line Distance Protection System”

Your email address will not be published. Required fields are marked *