You are currently viewing Features of Schneider Micom P111 Overcurrent & earth fault protection numerical relay

Features of Schneider Micom P111 Overcurrent & earth fault protection numerical relay

  • Post author:
  • Post category:Schneider

Schneider Micom P111 Statistical Relay is suitable for all applications needing overcurrent and earth fault protection numerical relay. Because of its reasonableness in addition to specialized highlights, the MiCOM P111 electrical transfers can be used both in medium and low – voltage applications. Their user-friendly design supplies a complete set of readily available measurements.

Schneider MiCOM P111 relay can be utilized where communication services are required plus their many functions allow for easy version in order to applications plus operational conditions.

MiCOM S1 setting software program enables easy configuration and access in order to all measurements. Within addition, the MODBUS RTU communication protocol enables interfacing with substation control or the SCADA system. MiCOM P111 is housed within a tiny case regarding rail or rack mounting.

Cost aggressive features permit complete measurements

MiCOM P111 relay gives adaptable current transfer, a total organization of estimations in addition to an assortment of proficient capacities at a cutthroat cost.

These are Models Available in DSG Enterprise: 

  • MiCOM P111L
  • MiCOM p111E
  • MiCOM P111A

Technical Detail features: Schneider Micom P111 Relay

  • 4CT 0 Binary Inputs / 3 Binary Outputs 8 LED’s,
  • Front USB,
  • Rear RS485 port for remote connection,
  • IEC 60870-5-103,
  • Modbus RTU,
  • Flush mounting (WxHxD: 106.5×106.5×118) – non draw-out case

Our own index of Schneider Micom Protection Electrical transfers gives driving in addition to dependable security and control for any sort of organization application. The particular latest Protection Relays also offer extensive security and reliability for your electric grid, from overcurrent and arc protection to distance plus differential protection associated with the transmission line. Our product variety offers solid protection with advanced marketing communications including the IEC 61850 to give you reassurance in safeguarding your grid.

Conclusion:-

All of us at Digital and Smart Grid Corporations with our nicely trained and experienced staff can assist you to get a custom-made remedy as per your own requirement. Contact us for the price of Schneider micom p111 overcurrent & earth fault protection numerical relay you can mail us at: info@dsgenterprises.in