GE / Alstom MiCOM Agile P14D Feeder Protection relay

SKU: Alstom_P14D Categories: ,

Description

GE / Alstom MiCOM Agile P14D Feeder Protection relay

GE / Alstom MiCOM Agile P14D Feeder Protection numerical relay provide advanced protection with flexibility, programmability and communications for maximum system reliability. Our highly skilled engineers and technicians understand distribution feeder principles and the sources of faults on overhead and underground distribution feeders. They apply their knowledge to the design and manufacture of some of the most advanced protection relays and systems in the world.
Major faults occurring in the distribution system such as arc flash, incipient cable splice fault, high impedance fault and others, must be sensed quickly and isolated immediately to prevent hazards to the general public and personnel. Learn how GE’s 8 Series, 350 and P40 Agile solutions provide early fault detection and warning in this spotlight application.

The P14N non-directional feeder, P14D directional feeder and P94V voltage and frequency IEDs bring the design rigour and technology of transmission applications to the entire utility and industrial market. The footprints of both the device physical size and the lifecycle environmental impact have been minimised using state-of-the-art design, component, and process selection. Agile solutions from GE are ideal for new-build and retrofit alike.
Agility and Versatility
MiCOM P40 Agile IEDs provide an integrated solution for the complete protection, control and monitoring of electrical power systems. Application for overhead lines, underground cables, busbars, breakers, transformers, reactors and distributed generation is supported, right from distribution (as primary protection) to transmission voltage levels (as back-up). The IEDs are suitable for a wide variety of applications in solidly-earthed, resistance-earthed and Petersen coil systems alike.

GE / Alstom MiCOM Agile P14D Feeder Protection numerical relay Key Benefits

• Comprehensive current, voltage, power and frequency protection
• Multi-stage independent protection elements
• Two stage circuit breaker failure and breaker condition monitoring
• Switchgear supervision including CT/VT, DC supply, full trip circuit supervision
• Support for multiple industry standard communication protocols including IEC 61850
• Compact, withdrawable design with 4”, 6”, and 8” case sizes for reduced space applications

 Explore the comprehensive range of GE feeder protection with us!

Reviews

There are no reviews yet.

Be the first to review “GE / Alstom MiCOM Agile P14D Feeder Protection relay”

Your email address will not be published. Required fields are marked *