GE / ALSTOM MiCOM Agile P642 transformer protection and Condition Monitoring system
Description
MICOM AGILE P642 TRANSFORMER PROTECTION
Technical Specification
• Type Numerical Relay
• Protection Type Transformer
• Voltage 24V-240V
• AC\DC Operated Auxillary supply AC/DC
Transformer Protection Systems MiCOM Agile P64
GE’s MiCOM Agile platform of transformer protection relays helps preserve transformer service life and provides fast protection for transformer faults. The platform consists of three model variants (P642, P643, and P645) that cover two and three-winding transformers (including auto-transformers), with up to five sets of 3-phase CT inputs, and offers high and low impedance restricted earth fault and has integral asset management capability.
Features of MiCOM Agile P642 transformer protection:
- High stability during external fault with heavy CT saturation due to transient bias technique
- No slow-down of differential elements due to 2nd harmonic component in fault currents
- Current transformer supervision operates with or without voltage inputs, fast enough to prevent any spurious tripping and alarm
- 10 integrated function keys, tri-color LEDs, and graphical programmable logic permit the creation of comprehensive, tailored schemes
Transformers are high capital assets in electrical power systems. Elimination of all electrical and mechanical stresses, although desirable to preserve transformer life, is impractical. Adaptive techniques to measure, alarm (or trip), and advise on cumulative service can help to schedule preventive maintenance before a costly failure occurs. Internal faults are a risk for all transformers, with short-circuits dissipating the highest localized energy. Unless cleared quickly, the possibility to rewind windings reduces and core damage may become irreparable.
GE’s P642, P643, and P645 address all these issues, preserving service life and offering fast protection for transformer faults. A transient bias technique has been included, enhancing relay stability and CT requirements. Hosted on an advanced IED platform, the P64x incorporates differential, REF, thermal, and over fluxing protection, plus backup protection for uncleared external faults. Model variants cover two and three-winding transformers (including auto-transformers), with up to five sets of 3-phase CT inputs.
Key benefits:
- Backup and logging of through faults
- Simple settings – wizard requires only nameplate data
- Integrated backup overcurrent per winding or CT input – optional directionalizing when relay fitted with a 3-phase VT Ordering the 3-phase VT permits full monitoring and measurement of power and energy quantities
Reviews
There are no reviews yet.