SCHNEIDER EASERGY FLAIR 22D- LITHIUM DUAL POWERED DIN AMMETRIC FPI
Description
SCHNEIDER EASERGY FLAIR 22D- LITHIUM DUAL POWERED DIN AMMETRIC FPI
Fault passage indicators for MV underground distribution networks
Part of PowerLogic
Fault passage indicators for MV underground distribution networks
Features
Phase and earth, three-phase Fault Passage Indicator (FPI) for local indication
- Flair 21D, 22D, 23DV: ammetric FPI, self powered by measurement sensors, integrated in MV switchgear or in a wall-mounted box.
- Flair 279 and 219: ammetric FPI, powered by LV supply and/or battery, wall-mounted installation
- Flair 3XX: directional FPI, powered by LV supply and/or battery, wall-mounted installation
Communicating Fault Passage Indicator (FPI) for remote monitoring
- Flair 200C: Three-phase default detector communicating for all type of neutral arrangement. In addition to the traditional detection functions, Flair 200C integrates functions of measurement and monitoring of the substation and data transmission.
Benefits
Reduce outage time and improve operation Profit from the 45 years of experience of a leader in fault passage indicators and telecommunication. With more than 400 000 units in operation, the Easergy range is the guarantee of complete peace of mind.
Applications
- MV distribution substation
- Various options to satisfy any type of MV networks and monitoring applications.
device short name | Flair 22D | |
range of product | Easergy Flair | |
product or component type | Fault passage indicator | |
range compatibility | RM6 SM6-24 SM6-36 Flusarc Premset FBX |
|
Rated voltage (Ur) | 3…36 kV | |
Main |
load current | 3 A | |
function available | Ammeter | |
inrush restraint duration | 0 s 3 s 70 s |
|
reset | Automatic reset 0…70 s upon current return 2 A or voltage return Factory reset 1…24 h By flush push-button External contact |
|
local signalling | 1 LED for fault indication External light indicator without battery Relay for fault indication Numerical display for faulty phase indication 1 LED for voltage presence phase to phase or phase to neutral 1 LED for voltage absence phase to phase or phase to neutral |
|
supply | via current transformer Li battery |
|
overcurrent protection | OFF Auto 100…800 A, adjustable in steps of 50 A |
|
Overcurrent fault | 5…30 A, adjustable in steps of 5 A 30…200 A, adjustable in steps of 10 A |
|
Time delay setting | Fault acknowledge time : 40…100 ms in steps of 20 ms Fault acknowledge time : 100…300 ms in steps of 50 ms |
|
communication port protocol | Without | |
battery life | 15 year(s) (in operation) | |
height | 48 mm | |
width | 96 mm | |
depth | 100 mm | |
net weight | 0.185 kg | |
Complementary |
electromagnetic compatibility | Electrostatic discharge – test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Electrostatic discharge – test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test – test level: 10 V/m, 80 MHz…1 GHz level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test – test level: 4 kV CM, 5kHz level 4 conforming to IEC 61000-4-4 Immunity to impulse waves – test level: 42 Ohm level 3 (on input-output) conforming to IEC 61000-4-5 Immunity to impulse waves – test level: 2 Ohm level 3 (on power supply) conforming to IEC 61000-4-5 Conducted RF disturbances – test level: 0.15…80 MHz, 10 V/m, 80 % MA (1 kHz) level 3 conforming to IEC 61000-4-6 Immunity to magnetic fields – test level: 30 A/m (permanent)-300 A/m (1 s) level 4 conforming to IEC 61000-4-8 Damped oscillating waves – test level: +/- 2.5 kV CM, +/- 1 kV DM, 1 MHz level 4 conforming to IEC 61000-4-12 |
|
mechanical robustness | Vibrations 9…200 Hz 1 gn 1 cycle conforming to IEC 60068-2-26 Seismic tests 2 gn horizontal position conforming to IEC 60068-2-29 Seismic tests 1 gn vertical position conforming to IEC 60068-2-29 Shocks 10 gn 11 ms 3 pulses in operation conforming to IEC 60068-2-27 |
|
IP degree of protection | Front panel: IP41 Other parts: IP30 |
|
IK degree of protection | IK07 conforming to IEC 62262 | |
ambient air temperature for operation | -40…70 °C | |
relative humidity | 95 % conforming to IEC 60068-2-30 | |
Environment |
Unit Type of Package 1 | PCE | |
Number of Units in Package 1 | 1 | |
Package 1 Weight | 241 g | |
Package 1 Height | 7.1 cm | |
Package 1 width | 11.1 cm | |
Package 1 Length | 13.7 cm | |
Unit Type of Package 2 | S04 | |
Number of Units in Package 2 | 48 | |
Package 2 Weight | 12 kg | |
Package 2 Height | 30 cm | |
Package 2 width | 40 cm | |
Package 2 Length | 60 cm | |
Packing Units |
Sustainable offer status | Green Premium product | |
REACh Regulation | REACh Declaration | |
EU RoHS Directive | Compliant EU RoHS Declaration |
|
Mercury free | Yes | |
RoHS exemption information | Yes | |
Offer Sustainability |