Siemens Siprotec 5 7SA86 Distance Protection Relay

SKU: SIPROTEC 7SA86 Categories: ,

Description

Siemens Siprotec 5 7SA86 Distance Protection Relay

The SIPROTEC 7SA86 distance protection relay has specifically been designed for the protection of lines. With its modular structure, flexibility and the powerful DIGSI 5 engineering tool, the SIPROTEC 7SA86 device offers future-oriented system solutions with high investment security and low operating costs.

7SA86 Distance Protection Relay Features

Main function:

  • Distance protection
  • Interoperability of SIPROTEC 5 and SIPROTEC 4 line protection devices

Tripping:

  • 3-pole, minimum tripping time: 9 ms

Inputs and outputs:

12 predefined standard variants with

  • 4/4 or 8/8 current transformers / voltage transformers,
  • 5 to 31 binary inputs,
  • 8 to 46 binary outputs

Hardware quantity structure:

  • Flexibly adjustable I/O quantity structure within the scope of the SIPROTEC 5 modular system

Housing width:

  • 1/3 × 19 inches to 2/1 × 19 inches

As standard:

  • Conformal coating

7SA86 Distance Protection Relay Functions

DIGSI 5 permits all functions to be configured and combined as required.

  • Minimum tripping time: 9 ms
  • 6 independent measuring loops (6-system distance protection)
  • Several distance-protection functions can be selected: Classic, reactance method (RMD), impedance protection for tranformers
  • Directional backup protection and various additional functions
  • Detection of ground faults of any type in compensated or isolated electrical power systems using the following functions: 3I0>, V0>, transient ground fault, cos φ, sin φ, harmonic, dir. Detection of intermittent ground faults and admittance
  • Ground fault detectionusing the pulse detection method
  • Adaptive power-swing blocking, out-of-step protection
  • Detection of current-transformer saturation for fast tripping with high accuracy
  • Fault locator Plus for accurate fault location with inhomogenous line sections and targeted automatic overhead line section reclosing (AREC)
  • Arc protection
  • Automatic frequency relief for underfrequency load shedding, taking changed infeed conditions due to decentralized power generation into consideration
  • Power protection, configurable as active or reactive power protection
  • Directional reactive power undervoltage protection (QU protection)
  • Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as thermal overload protection) and operational measured values
  • 3-pole automatic reclosing function
  • Control, synchrocheck and switchgear interlocking protection
  • Graphical logic editor to create powerful automation functions in the device
  • Single-line representation in small or large display
  • Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
  • Up to 4 pluggable communication modules, usable for different and redundant protocols (IEC 61850-8-1, IEC 61850-9-2Client, IEC 61850-9-2 Merging Unit, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)
  • Serial protection data communication via optical fibers, two-wire connections and communication networks  (IEEE C37.94,and others), including automatic switchover between ring and chain topology
  • Reliable data transmission via PRP and HSR redundancy protocols
  • Extensive cyber securityfunctionality, such as role-based access control (RBAC), protocolling security-related events or signed firmware
  • Simple, quick and secure access to device data via a standard Web browser – without additional software
  • Phasor measurement unit (PMU)for synchrophasor measured values and IEEE C37.118 protocol
  • Time synchronization using IEEE 1588
  • Powerful fault recording (buffer for a max. record time of 80 sec. at 8 kHz or 320 sec. at 2 kHz)
  • Auxiliary functions for simple tests and commissioning
  • Flexibly adjustable I/O quantity structure within the scope of the SIPROTEC 5 modular system

Applications

  • Detection and selective 3-pole tripping of short circuits in electrical equipment of star networks, lines with infeed at one or two ends, parallel lines and open-circuited or closed ring systems of all voltage levels
  • Detection of ground faults in isolated or arc-suppression-coil-ground power systems in star, ring, or meshed arrangement
  • Backup protection for differential protection devices of all kind for lines, transformers, generators, motors, and busbars
  • Serial protection communication with SIPROTEC 5 and SIPROTEC 4 devices over different distances and physical media, such as optical fiber, two-wire connections, and communication networks
  • Phasor Measurement Unit (PMU)

Benefits

  • Safety due to powerful protection functions
  • Data security and transparency over the entire lifecycle of the plant, saving time and money
  • Purposeful and easy handling of devices and software thanks to a user-friendly design
  • Increased reliability and quality of the engineering process
  • Cyber securityin accordance with NERC CIP and BDEW Whitepaper requirements
  • Highest availability even under extreme environmental conditions  by “conformal coating“ of electronic boards
  • Powerful communication components warrant safe and effective solutions
  • Full compatibility between IEC 61850 Editions 1 and 2
  • High investment security and low operating costs due to future-oriented system solutions

SIPROTEC 5 is part of the new generation of incomparable modular, flexible, and intelligent digital field devices. With modularly designed hardware and software and its high-performance DIGSI 5 engineering tool, the SIPROTEC 5 product family of field devices are perfect for protection, control, monitoring, and measuring applications in electrical energy systems. SIPROTEC 5 offers a wide product range with modular elements for every application and requirement.

 

 

 