action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/functions.php on line 6114Technical Specification \u2022 Type Numerical Relay \u2022 Protection Type Feeder<\/p>\n
P40 Agile Feeder Management<\/strong><\/p>\n The Alstom Agile P14DB11A2C0620A, P14N non-directional feeder, P14D directional feeder, and P94V voltage and frequency IEDs bring the design rigour and technology of transmission applications to the entire utility and industrial market. The footprints of both the device physical size and the lifecycle environmental impact have been minimised using state-of-the-art design, component, and process selection. Agile solutions from GE are ideal for new-build and retrofit alike.<\/p>\n Agility and Versatility<\/strong><\/p>\n MiCOM P40 Agile IEDs provide an integrated solution for the complete protection, control, and monitoring of electrical power systems. Application for overhead lines, underground cables, busbars, breakers, transformers, reactors, and distributed generation is supported, right from distribution (as primary protection) to transmission voltage levels (as back-up). The IEDs are suitable for a wide variety of applications in solidly-earthed, resistanceearthed, and Petersen coil systems alike.<\/p>\n Protection and Control<\/strong><\/p>\n \u0001 Comprehensive current, voltage, power, and frequency protection functions<\/p>\n \u0001 Multi-stage independent protection elements, variety of curves in 4 setting groups<\/p>\n \u0001 High Impedance Fault, Load Encroachment, Switch onto fault and Fault Locator<\/p>\n \u0001 Rate of change, full-scheme auto-reclose, TEFD and synchrocheck<\/p>\n <\/p>\n Metering and Monitoring<\/strong><\/p>\n \u0001 Comprehensive metering & power-up diagnostics<\/p>\n \u0001 Two stage circuit breaker failure and breaker condition monitoring<\/p>\n \u0001 Switchgear supervision including CT\/VT, DC supply, full Trip Circuit Supervision, CB failure<\/p>\n \u0001 Switch control and status (up to 8) and up to 2048 events and 10.5 s disturbance records<\/p>\n AdvancedCommunications<\/strong><\/p>\n \u0001 Up to two Ethernet ports with options for redundancy protocols (RSTP or PRP\/HSR)<\/p>\n \u0001 SNTP or IRIG-B time synchronization<\/p>\n \u0001 Multiple communication protocols including IEC 61850, Modbus, DNP 3.0, IEC 60870-5-103 and Courier\/K-Bus<\/p>\n \u0001 Support IEC 61850 and DNP3 Ethernet protocol working concurrently<\/p>\n