\u2022 Type Numerical Relay<\/p>\n
\u2022 Protection Type Transformer<\/p>\n
\u2022 Voltage 24V-240V<\/p>\n
\u2022 AC\\DC Operated Auxillary supply AC\/DC<\/p>\n
Transformer Protection Systems MiCOM Agile P64<\/p>\n
GE’s MiCOM Agile platform of transformer protection relays helps preserve transformer service life and provides fast protection for transformer faults. The platform consists of three model variants (P642, P643, and P645) that cover two and three-winding transformers (including auto-transformers), with up to five sets of 3-phase CT inputs, and offers high and low impedance restricted earth fault and has integral asset management capability.<\/p>\n
Features of MiCOM Agile P642 transformer protection:<\/p>\n
Transformers are high capital assets in electrical power systems. Elimination of all electrical and mechanical stresses, although desirable to preserve transformer life, is impractical. Adaptive techniques to measure, alarm (or trip), and advise on cumulative service can help to schedule preventive maintenance before a costly failure occurs. Internal faults are a risk for all transformers, with short-circuits dissipating the highest localized energy. Unless cleared quickly, the possibility to rewind windings reduces and core damage may become irreparable.<\/p>\n
GE’s P642, P643, and P645 address all these issues, preserving service life and offering fast protection for transformer faults. A transient bias technique has been included, enhancing relay stability and CT requirements. Hosted on an advanced IED platform, the P64x incorporates differential, REF, thermal, and over fluxing protection, plus backup protection for uncleared external faults. Model variants cover two and three-winding transformers (including auto-transformers), with up to five sets of 3-phase CT inputs.<\/p>\n
Key benefits:<\/p>\n