action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/functions.php on line 6114ABB Unigear type ZN1 \u2013 an innovative switchgear for power Distribution requirements<\/p>\n
ABB ZN1 primary distribution switchgear is designed to meet the specific needs of the Indian market, with key features such as a compact construction, low maintenance design and an internal arc withstand current rating of 26.3 kA for 1 second that is unique in this sector. The ZN1 range provides an access to the quality, reliability, safety, performance and high level of technical support associated with ABB\u2019s global brand.<\/p>\n
ZN1 Switchgear<\/strong><\/p>\n ABB\u2019s medium voltage switchgear ZN1 contains our knowhow and expertise on air insulated switchgear, and is designed to meet the specific needs of our customers. ZN1<\/p>\n comes with the very best of design and quality built-in to deliver an ideal solution for a wide variety of power distribution needs.<\/p>\n \u2013\u2013 Switchgear conforms to IEC 62271-200<\/p>\n \u2013\u2013 Designed for classification LSC2B – PM<\/p>\n \u2013\u2013 Designed for fast and easy installation<\/p>\n \u2013\u2013 Constructed using aluminium zinc coated steel and pre galvanised sheets making it a highly reliable switchgear<\/p>\n \u2013\u2013 Extensible on both sides<\/p>\n \u2013\u2013 Encapsulated PTs with built in fuses<\/p>\n \u2013\u2013 Cable termination height of 600 mm<\/p>\n \u2013\u2013 Factory assembled integral gas duct<\/p>\n \u2013\u2013 Simple maintenance<\/p>\n \u2013\u2013 Compact and space saving solution with reduced footprints<\/p>\n \u2013\u2013 Fitted with conventional instrument transformers<\/p>\n \u2013\u2013 Can be offered with ABB\u2019s REF601,REJ601 and other numerical relays for intelligent protection solutions<\/p>\n Safety<\/strong><\/p>\n \u2013\u2013 Internal arc-proof construction conforming to the classification IAC AFLR up to 26.3kA,1 sec<\/p>\n \u2013\u2013 Closed door rack-in and rack-out of circuit breaker ensuring full safety to the operating personnel<\/p>\n \u2013\u2013 Fitted with standard safety interlocks<\/p>\n \u2013\u2013 Provisions of padlocks on shutter, circuit breaker compartment doors, rack in handle insertion<\/p>\n VInd \u2013 Vacuum circuit breaker<\/p>\n \u2013\u2013 Conforms to IEC 62271-100<\/p>\n \u2013\u2013 Floor rolling circuit breaker<\/p>\n \u2013\u2013 Continuous rated closing and tripping coils<\/p>\n \u2013\u2013 Modular circuit breaker mechanism for fast and easy maintenance<\/p>\n \u2013\u2013 Integral spring charging handle<\/p>\n \u2013\u2013 Suitable for E2,M2 & C2 (single capacitor bank) class applications<\/p>\n \u2013\u2013 In-built mechanical anti-pumping device<\/p>\n <\/p>\n ZN1 with single busbar system<\/strong><\/p>\n <\/p>\nABB Unigear type ZN1 Key features<\/strong><\/h2>\n
\n\n
\n Switchgear<\/strong><\/td>\n ZN1<\/strong><\/td>\n<\/tr>\n \n Rated voltage<\/td>\n <\/td>\n <\/td>\n <\/td>\n [kV]<\/td>\n 12<\/td>\n<\/tr>\n \n Rated insulation voltage<\/td>\n <\/td>\n <\/td>\n <\/td>\n [kV]<\/td>\n 12<\/td>\n<\/tr>\n \n Rated power frequency withstand voltage<\/td>\n <\/td>\n <\/td>\n <\/td>\n [kV 1 min]<\/td>\n 28<\/td>\n<\/tr>\n \n Rated lightning impulse withstand voltage<\/td>\n <\/td>\n <\/td>\n <\/td>\n [kV]<\/td>\n 75<\/td>\n<\/tr>\n \n Rated frequency<\/td>\n <\/td>\n <\/td>\n <\/td>\n [Hz]<\/td>\n 50<\/td>\n<\/tr>\n \n Rated short time withstand current<\/td>\n <\/td>\n <\/td>\n <\/td>\n [kA 3s]<\/td>\n 26.3<\/td>\n<\/tr>\n \n Peak current<\/td>\n <\/td>\n <\/td>\n <\/td>\n [kA]<\/td>\n 65.75<\/td>\n<\/tr>\n \n Internal arc withstand current<\/td>\n <\/td>\n <\/td>\n <\/td>\n [kA 1s]<\/td>\n 26.3<\/td>\n<\/tr>\n \n Main busbar rated current<\/td>\n <\/td>\n <\/td>\n <\/td>\n [A]<\/td>\n 1250 – 2000<\/td>\n<\/tr>\n \n Branch connection rated current<\/td>\n <\/td>\n <\/td>\n <\/td>\n [A]<\/td>\n 1250<\/td>\n<\/tr>\n \n Internal Arc Classification to IEC 62271-200<\/td>\n IAC AFLR<\/td>\n<\/tr>\n \n Overall dimensions of basic cubicle<\/td>\n <\/td>\n <\/td>\n <\/td>\n <\/td>\n <\/td>\n<\/tr>\n \n <\/td>\n H<\/td>\n <\/td>\n <\/td>\n<\/tr>\n \n <\/td>\n <\/td>\n <\/td>\n <\/td>\n W [mm]<\/td>\n 600<\/td>\n<\/tr>\n \n <\/td>\n <\/td>\n W<\/td>\n D<\/td>\n D [mm]<\/td>\n 1500 (without line PT) , 2050 (with line PT)<\/td>\n<\/tr>\n \n Clearance required on for maintenance on front<\/td>\n <\/td>\n <\/td>\n <\/td>\n [m]<\/td>\n 1.5<\/td>\n<\/tr>\n \n Clearance required on for maintenance on rear<\/td>\n <\/td>\n <\/td>\n <\/td>\n [m]<\/td>\n 1<\/td>\n<\/tr>\n \n Clearance required on for maintenance on sides<\/td>\n <\/td>\n <\/td>\n <\/td>\n [m]<\/td>\n 1<\/td>\n<\/tr>\n \n Cable connection height<\/td>\n <\/td>\n <\/td>\n <\/td>\n [mm]<\/td>\n 600<\/td>\n<\/tr>\n \n Paint shades [For front door and end covers only]<\/td>\n RAL7035 Light Grey (other shades on request)<\/td>\n<\/tr>\n \n Approximate weight<\/td>\n <\/td>\n <\/td>\n <\/td>\n [Kg]<\/td>\n 600<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n