Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the ninja-forms domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/functions.php on line 6114
Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the hustle domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/functions.php on line 6114
Warning: Cannot modify header information - headers already sent by (output started at /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/functions.php:6114) in /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/rest-api/class-wp-rest-server.php on line 1893
Warning: Cannot modify header information - headers already sent by (output started at /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/functions.php:6114) in /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/rest-api/class-wp-rest-server.php on line 1893
Warning: Cannot modify header information - headers already sent by (output started at /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/functions.php:6114) in /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/rest-api/class-wp-rest-server.php on line 1893
Warning: Cannot modify header information - headers already sent by (output started at /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/functions.php:6114) in /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/rest-api/class-wp-rest-server.php on line 1893
Warning: Cannot modify header information - headers already sent by (output started at /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/functions.php:6114) in /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/rest-api/class-wp-rest-server.php on line 1893
Warning: Cannot modify header information - headers already sent by (output started at /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/functions.php:6114) in /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/rest-api/class-wp-rest-server.php on line 1893
Warning: Cannot modify header information - headers already sent by (output started at /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/functions.php:6114) in /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/rest-api/class-wp-rest-server.php on line 1893
Warning: Cannot modify header information - headers already sent by (output started at /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/functions.php:6114) in /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/rest-api/class-wp-rest-server.php on line 1893
{"id":349,"date":"2020-08-19T11:50:36","date_gmt":"2020-08-19T11:50:36","guid":{"rendered":"http:\/\/www.dsgenterprisesltd.com\/product\/import-placeholder-for-25079\/"},"modified":"2022-05-31T07:40:41","modified_gmt":"2022-05-31T07:40:41","slug":"siemens-siprotec-5-7sj86-overcurrent-feeder-protection-relay","status":"publish","type":"product","link":"https:\/\/dsgenterprisesltd.com\/product\/siemens-siprotec-5-7sj86-overcurrent-feeder-protection-relay\/","title":{"rendered":"Siemens Siprotec 5 7SJ86 Overcurrent & Feeder Protection Relay"},"content":{"rendered":"
The feeder and overcurrent protection SIPROTEC 7SJ86 is part of the new SIPROTEC 5 series of modular, flexible and intelligent digital field devices.With its modularity and flexibility and its high-performance DIGSI 5 engineering tool, the SIPROTEC 7SJ86 fits perfectly for protection, control, monitoring, and measuring applications in electrical energy systems and for reserve or emergency protection for the line protection devices.<\/p>\n
Main function:<\/strong><\/p>\n
Overcurrent protection<\/p>\n
Tripping:3-poleInputs and outputs:-3 predefined standard variants with 4\/4-current\/voltage transformers,-11 to 23 binary inputs,-9 to 25 binary outputsHardware flexibility:Flexibly adjustable and expandable I\/O quantity structure within the scope of the SIPROTEC 5 modular systemHousing width:1\/3 x 19” to 2\/1 x 19”<\/p>\n
All functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.<\/p>\n
\n
Overcurrent protection as backup \/ emergency line protection for all voltage levels with 3-pole tripping<\/li>\n
Optimized tripping times due to directional comparison and protection data communication<\/li>\n
Detection of ground faults of any type in isolated or arc-suppression-coil-ground systems using the following functions: 3I0>, V0>, fleeting contact, Cos-\/SinPhi, harmonic, dir. detection of intermittent ground faults and admittance<\/li>\n
Ground fault detection using the pulse location method<\/li>\n
Arc protection<\/li>\n
Automatic frequency relief for load shedding in case of underfrequency, taking account of changed infeed conditions due to decentralized power generation<\/li>\n
Overvoltage and undervoltage protection<\/li>\n
Frequency protection and frequency change protection for load shedding applications<\/li>\n
Power protection, configurable as active or reactive power protection<\/li>\n
Protection functions for capacitor banks, such as overcurrent, overload, current unbalance, peak overvoltage, or differential protection<\/li>\n
Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as thermal overload protection) and operational measured values<\/li>\n
Control, synchrocheck and switchgear interlocking protection<\/li>\n
Circuit-breaker failure protection<\/li>\n
Circuit-breaker reignition monitoring<\/li>\n
Graphical logic editor to create powerful automation functions in the device<\/li>\n
Single line representation in small or large display<\/li>\n
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)<\/li>\n
4 optional pluggable communication modules, usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)<\/li>\n
Serial protection data communication via optical fibers, two-wire connections and communication networks (IEEE C37.94, and others), including automatic switchover between ring and chain topology<\/li>\n
Redundancy protocols PRP and HSR<\/li>\n
Cyber security to NERC CIP and BDWE Whitepaper requirements<\/li>\n
Phasor Measurement Unit (PMU) for synchrophasor measured values and IEEE C37.118 protocol<\/li>\n
Time synchronization using IEEE 1588<\/li>\n
Powerful fault recording (buffer for a max. record time of 80 sec. at 8 kHz or 320 sec. at 2 kHz)<\/li>\n
Auxiliary functions for easy tests and commissioning<\/li>\n
Flexibly adjustable I\/O quantity structure within the scope of the SIPROTEC 5 modular system<\/li>\n<\/ul>\n