action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home2/reliserv/public_html/dsgenterprisesltd/wp-includes/functions.php on line 6114The SICAM Fault Collector Gateway (FCG) device receives both the load current values and distribution line faults via the SICAM Fault Sensor Indicator (FSI). The received information status and events are transmitted to the control center based on the IEC 60870-5-104 protocol or to the Siemens FLiC service using the XMPP protocol. The fault detected by SICAM FSI is communicated to Siemens SICAM FCG Gateway via short-range radio (SRR) communication within a distance of 100 meters. SICAM FCG provides 6 binary inputs and 3 binary outputs. SICAM FCG can be configured and diagnosed locally using the Web GUI by connecting to a PC or laptop computer or remotely via General Packet Radio Service (GPRS). The SICAM FCG has a plastic housing and it is strongly recommended to mount it within a metal cabinet for additional protection. The Global System for Mobile Communications (GSM) and short-range radio antenna are mounted outside the metallic cabinet. SICAM FSI firmware and parameters can be updated from the SICAM FCG. SICAM FCG Web GUI allows you to configure the parameters, display error and event log, upgrade of firmware, and download the configuration.<\/p>\n
Functions<\/strong><\/p>\n Binary interfaces<\/strong><\/p>\n Communication<\/strong><\/p>\n GSM module<\/strong><\/p>\n Short-range radio module<\/strong><\/p>\n Time synchronization<\/strong><\/p>\n In operation, the device needs the date and time for all time-relevant processes. This ensures a uniform time basis and a time stamp for the communication with peripheral devices. The following types of time synchronization are performed according to the parameterization:<\/p>\n Siemens SICAM FCG Gateway Applications<\/strong><\/p>\n Unplanned outages<\/strong><\/p>\n Keeping your grids up and running<\/b><\/p>\n Using sophisticated tools and solutions for fast grid restoration<\/p>\n Unplanned outages cannot always be avoided. Flexible solutions for local and remote monitoring enable the fast and efficient restoration of cable grids and overhead lines.<\/p>\n Operational savings<\/strong><\/p>\n Optimizing business operations<\/strong><\/p>\n Comprehensive and efficient ways for municipalities and DSOs to get the most out of their efforts.<\/p>\n The growing demand for power from industries and households can be fulfilled simply. With modern technologies and innovative solutions such as optimized voltage and capacity management, self-healing grids, and by avoiding losses of any kind.<\/p>\n Fault localization<\/b><\/p>\n Fault reporting \u2013 fast, flexible, and direct\u00a0<\/b><\/p>\n Fault localization in the cloud \u2013 the cloud-based service for fault detection by Siemens<\/span><\/p>\n The basis for fast and efficient fault management was previously bound to the control room. Fault localization in the cloud is a new, cloud-based service, which makes it possible to send fault information \u2013 including the fault location \u2013 directly to the maintenance crews, without the need for a grid control center.<\/span><\/p>\n\n
\nThese binary inputs have selectable thresholds of DC 19 V, DC 88 V, or DC 176 V.
\nTherefore an optimal adjustment to the pickup voltage can be made in the case of increased interference level.
\nThe binary outputs are designed as relay contacts. The terminal block P has 2 relay outputs Normally open (NO) and one relay output change over (CO). The relays can switch voltages up to AC\/DC 250 V and currents up to AC\/DC 5 A.<\/li>\n<\/ul>\n\n
\nThe various device communication interfaces and protocols are available for the communication between the SICAM FCG and the control center.
\nSICAM FCG has an Ethernet interface which supports the device parameterization and the monitoring.
\nThe communication interface supports the device parameterization and the transmission of messages and measured values. The information is transmitted in telegrams in a secured way.<\/li>\n<\/ul>\n\n
\nThe communication to the control center can be executed based on the IEC 60870-5-104 via internet protocol security (IPSec) tunnel and GSM.
\nYou can execute the configuration and local diagnostic remotely via GSM. The communication to the Siemens FLiC service is based on XMPP and GSM.<\/li>\n<\/ul>\n\n